129,00
Op voorraad
Voor 23:59 uur besteld, woensdag in huis
TFI 812.2 Model 10:Pre-ignition time approx. 10 sec.appropriate nominal capacityaccording to the appliance standortor the gas appliance directive.Technical Data:Supply voltage 220 / 240 V (-15... +10%)50 Hz (40 - 60 Hz)Fuse rating 10 A rapid or 6 A slowPower consumption 5 VAMax. current peroutput terminal 4 AMax. current total 6 APre-ignition time 15 or 10 sec.Delay, post-ignition time noneSafety interval 5 or 10 sec.2nd stage delay approx. 20 sec.Reset delay after lockout approx. 60 sec.Permissible ambient temperature -20° C to +60° CSensitivity 1.5 µAMin. ionisation current required 2 - 3 µAIonisation probe insulation probe - earthgreater than 50 MΩStray capacitance probe - earthless than 1000 pF(max. 20 m cable)Insulation standard IP 44Weight incl. baseplate 250 gMounting attitude any